☣️ UN 1608 • CLASS 6

UN 1608 — Ferrous arsenate

Placard: Toxic. ERG Guide 151. Training/quick-reference only — use current ERG + SOP/SOG for incident-specific actions.

🚒☣️
⚠️ This page is a quick-reference aid. For real incidents: stage upwind, isolate, deny entry, request Hazmat early, and consult the current ERG + SOP/SOG.

UN 1608 is Ferrous arsenate, a toxic arsenic-containing material assigned to ERG Guide 151. The key responder concern is preventing inhalation of dust or fumes and preventing contaminated runoff.

Hazard overview: UN 1608 presents arsenic dust, fume and ingestion hazards. Heating or fire can create toxic arsenic-containing fumes, and dry powder can contaminate clothing, equipment and surfaces.

Response guidance: For a UN 1608 incident, responders should verify the product with shipping papers, package markings, SDS and ERG Guide 151. Establish incident command, isolate the area, stay upwind, prevent dust or vapor exposure, control runoff and choose entry or cleanup actions based on monitoring, SDS and local SOP.

Firefighter training notes: Training for UN 1608 should emphasize arsenic dust/fume exposure, contamination control, SCBA use, runoff containment and decontamination. Common errors include treating nonflammable toxic solids as low risk and spreading dust during cleanup. Use ERG 151, SDS and local SOP.

Regulatory context: Ferrous arsenate is regulated as a toxic arsenic hazardous material. Transportation, workplace exposure, spill reporting, waste handling, storage and environmental requirements may vary by compound, concentration, quantity and jurisdiction. Verify current requirements through shipping papers, SDS, facility documents and applicable DOT, OSHA, EPA, NFPA, state or local authority guidance.

Storage & handling: Ferrous arsenate should be stored in tightly closed compatible containers in a secure, cool, dry, well-ventilated toxic-material area away from food, incompatible chemicals, heat and unauthorized access. Prevent dust release, leaks and contaminated runoff.

Advertisement

UN 1608 Quick Details

UN 1608
Product name: Ferrous arsenate
DOT Class: 6
Placard type: Toxic
ERG Guide: 151 (check current ERG)
Initial isolation: ERG 151: isolate spill 25m all directions; large spill isolate 50m, consider evacuation 300m downwind

Common Hazards of UN 1608

  • HIGHLY TOXIC arsenic-containing material; may be fatal if inhaled, ingested or absorbed through skin.
  • Dust or powder can create a serious inhalation and contamination hazard.
  • Avoid skin contact and prevent dust from becoming airborne.
  • Fire or heating may produce toxic arsenic-containing fumes.
  • Runoff from fire control or spill control may pollute waterways.
  • Containers may rupture or fail when heated.
  • Specific toxicity and solubility depend on the exact arsenic compound.

Chemical Identity & Physical Properties

Gray to greenish-gray odorless solid powder or granular material at room temperature.

Also known asIron(II) arsenateFerrous arsenate dibasicIron arsenateArsenate de fer
CAS Number10102-49-5
AppearanceGray to greenish-gray odorless solid powder or granular material at room temperature.
Flash PointNot applicable (non-combustible solid)
Boiling PointNot applicable (decomposes before boiling)
Vapor DensityNot applicable (solid)
Water ReactivitySlowly soluble in water; may release toxic arsenic compounds in solution
Chemical details are general reference only. Always verify with current SDS, ERG, and SOP/SOG.

Fireground Response Guidance — UN 1608

Extinguishing Media

Use extinguishing agents appropriate for the surrounding fire and SDS. Water spray may cool containers or reduce dust only when runoff can be controlled as toxic contamination.

PPE Requirements

⚠️ Level A or B required; full-face SCBA, chemical-resistant suit, double gloves; prevent any skin contact

Use positive-pressure SCBA for dust, mist, fumes, fire or confined-space exposure. Chemical-resistant gloves, eye/face protection and protective clothing should be selected from SDS; avoid all skin contact and contaminated dust.

Isolation & Evacuation

ERG 151: isolate spill 25m all directions; large spill isolate 50m, consider evacuation 300m downwind
Always confirm protective actions with the current edition of the Emergency Response Guidebook (ERG Guide 151).

First Actions for a UN 1608 Incident

  • CALL 911. Then call the emergency response telephone number on the shipping paper, if available.
  • Keep unauthorized personnel away.
  • Stay upwind, uphill and/or upstream.
  • Avoid breathing vapors, fumes, dust or mist and avoid all skin or eye contact.
  • Do not touch or walk through spilled material unless properly trained and wearing appropriate protective equipment.
  • Avoid creating dust clouds or spreading contaminated liquid, powder, molten material or runoff.
  • Ventilate closed spaces before entering, but only if properly trained, equipped, monitored and authorized by incident command.
  • Isolate the spill or leak area and expand the perimeter if vapor, dust, fire involvement or unknown concentration is present.
  • Use ERG Guide 151, shipping papers, SDS, air monitoring and incident command for protective actions.
Advertisement

📋 Copy & Share Field Card

UN 1608 — Ferrous arsenate
HAZMAT RADIO NOTE — UN 1608 Product: Ferrous arsenate Class 6 / Toxic / ERG 151 PPE: Level A or B required; full-face SCBA, chemical-resistant suit, double gloves; prevent any skin contact ISOLATION: ERG 151: isolate spill 25m all directions; large spill isolate 50m, consider evacuation 300m downwind ACTION: Stage upwind · Isolate · Deny entry · Request HazmatRADIO

Use for: Quick radio or face-to-face size-up. Short, structured, field-ready.

SMS WhatsApp
=== IC HAZMAT BRIEFING === UN 1608 — Ferrous arsenate Class: 6 | Placard: Toxic | ERG Guide: 151 Appearance: Gray to greenish-gray odorless solid powder or granular material at room temperature. Water Reactivity: Slowly soluble in water; may release toxic arsenic compounds in solution Extinguishing: Use extinguishing agents appropriate for the surrounding fire and SDS. Water spray may cool containers or reduce dust only when runoff can be controlled as toxic contamination. PPE: Level A or B required; full-face SCBA, chemical-resistant suit, double gloves; prevent any skin contact Isolation: ERG 151: isolate spill 25m all directions; large spill isolate 50m, consider evacuation 300m downwind — Key Hazards — • HIGHLY TOXIC arsenic-containing material; may be fatal if inhaled, ingested or absorbed through skin. • Dust or powder can create a serious inhalation and contamination hazard. • Avoid skin contact and prevent dust from becoming airborne. — First Actions — • CALL 911. Then call the emergency response telephone number on the shipping paper, if available. • Keep unauthorized personnel away. • Stay upwind, uphill and/or upstream. • Avoid breathing vapors, fumes, dust or mist and avoid all skin or eye contact. SOURCE: allfirefighter.com/hazmat/un/ferrous-arsenate-un-1608 | Always use current ERG + SOP/SOGIC BRIEFING

Use for: Incident command briefing, staging area whiteboard, or pre-entry team brief.

SMS (short)
UN1608 Ferrous arsenate Cls6 ERG151 | allfirefighter.com/hazmat/un/ferrous-arsenate-un-1608SMS / 160 CHAR

Use for: Quick text to command or incoming units. Fits in a single SMS.

⚠️ Quick-reference only. Always use current ERG + SOP/SOG for incident-specific actions. Page: https://allfirefighter.com/hazmat/un/ferrous-arsenate-un-1608

Related UN Numbers in Class 6

Discovery block for training / quick reference. Always consult the current ERG + your SOP/SOG for operations.
Advertisement

Frequently Asked Questions about UN 1608

UN 1608 is Ferrous arsenate, a hazardous material assigned to ERG Guide 151.

No. It is generally not flammable, but fire or heating can produce toxic arsenic-containing fumes.

ERG Guide 151 applies to UN 1608 for initial isolation, protective actions and first response guidance.

UN 1608 presents arsenic dust, fume and ingestion hazards. Heating or fire can create toxic arsenic-containing fumes, and dry powder can contaminate clothing, equipment and surfaces.

Use positive-pressure SCBA for dust, mist, fumes, fire or confined-space exposure. Chemical-resistant gloves, eye/face protection and protective clothing should be selected from SDS; avoid all skin contact and contaminated dust.

Arsenic dust or fumes can contaminate clothing, equipment and surfaces and may be dangerous by inhalation or ingestion.
Sources (high level): DOT/PHMSA marking & class concepts + ERG usage principles. This page does not reproduce ERG guide text—always consult the current ERG for incident-specific protective actions.