UN 1379 — Paper, unsaturated oil treated
Placard: Spontaneously Combustible. ERG Guide 133. Training/quick-reference only — use current ERG + SOP/SOG for incident-specific actions.
UN 1379 is Paper, unsaturated oil treated, a self-heating or spontaneously combustible material assigned to ERG Guide 133. The main hazard is hidden heat buildup that can lead to smoldering, open flame or re-ignition.
Hazard overview: UN 1379 presents self-heating, smoldering fire and re-ignition hazards. Disturbing hot material can introduce oxygen and intensify burning, while smoke may contain carbon monoxide and irritating combustion products.
Response guidance: For a UN 1379 incident, responders should verify the product with shipping papers, package markings, SDS and ERG Guide 133. Establish incident command, isolate the area, stay upwind, avoid unnecessary disturbance of powder, piles or damaged packaging, and use only extinguishing agents compatible with the specific material.
Firefighter training notes: Training for UN 1379 should emphasize self-heating, smoldering piles, oxygen exposure during overhaul, thermal monitoring and re-ignition. Common errors include opening hot piles too aggressively and ending operations before deep-seated heat is controlled.
Regulatory context: Paper, unsaturated oil treated is regulated as a hazardous material for transportation and emergency response purposes. Transportation, workplace exposure, spill reporting, waste handling, storage and environmental requirements may vary by formulation, quantity and jurisdiction. Verify current requirements through shipping papers, SDS, facility documents and applicable DOT, OSHA, EPA, NFPA, state or local authority guidance.
Storage & handling: Paper, unsaturated oil treated should be stored to prevent self-heating, oil/moisture contamination where relevant, compacted hot spots and ignition exposure. Keep piles, bales or packages ventilated where appropriate and inspect for heat, odor or smoke according to facility procedures.
UN 1379 Quick Details
Common Hazards of UN 1379
- May self-heat and ignite when damp, oily, contaminated, compacted or stored in bulk.
- Piles, sacks, bales or rolls may retain heat and smolder internally before open flame is visible.
- Disturbing hot material may introduce oxygen and intensify smoldering or flame spread.
- Fire may produce irritating or toxic smoke including carbon monoxide.
- Runoff from fire control may carry organic or oily contamination.
- Large quantities may require prolonged overhaul and thermal monitoring.
- Material may re-ignite after apparent extinguishment.
Chemical Identity & Physical Properties
Sheets or rolls of paper treated with unsaturated oils (e.g., linseed oil). Typically tan to brown in color. Solid material that is prone to spontaneous heating due to oxidation of the oil.
| Also known as | Oil-treated paperLinseed oil paperDrying oil-impregnated paperSelf-heating paper |
| Appearance | Sheets or rolls of paper treated with unsaturated oils (e.g., linseed oil). Typically tan to brown in color. Solid material that is prone to spontaneous heating due to oxidation of the oil. |
| Flash Point | Variable depending on oil content; typically 38-93°C (100-200°F) |
| Boiling Point | Not applicable (solid material) |
| Vapor Density | Not applicable (solid material) |
| Water Reactivity | No significant reaction with water |
Fireground Response Guidance — UN 1379
Extinguishing Media
PPE Requirements
Use SCBA for smoke, smoldering material, dust or confined-space operations. Wear protective clothing and gloves appropriate for hot organic material, contaminated runoff and extended overhaul conditions.
Isolation & Evacuation
First Actions for a UN 1379 Incident
- CALL 911. Then call the emergency response telephone number on the shipping paper, if available.
- Keep unauthorized personnel away.
- Stay upwind, uphill and/or upstream.
- Check for heat, smoke, odor or smoldering before disturbing piles, bales, sacks or containers.
- Avoid breaking apart hot material unless incident command has a controlled plan for exposure, extinguishment and overhaul.
- Isolate the area and remove ignition sources if it is safe to do so.
- Use thermal imaging, monitoring and extended overhaul where available.
- Use ERG Guide 133, shipping papers, SDS and local SOP for protective actions and fire-control decisions.