☣️ UN 1810 • CLASS 6

UN 1810 — Phosphorus oxychloride

Placard: Toxic. ERG Guide 137. Training/quick-reference only — use current ERG + SOP/SOG for incident-specific actions.

🚒☣️
⚠️ This page is a quick-reference aid. For real incidents: stage upwind, isolate, deny entry, request Hazmat early, and consult the current ERG + SOP/SOG.

UN 1810 is Phosphorus oxychloride, a toxic corrosive phosphorus halide assigned to ERG Guide 137. Water or moist air can trigger strong heat release and dense corrosive hydrogen halide fumes.

Hazard overview: UN 1810 presents violent water reaction, toxic/corrosive fume, heavy vapor and acidic-runoff hazards. Avoid water and foam on the product unless specialist guidance confirms a safe use.

Response guidance: For a UN 1810 incident, responders should verify the product with shipping papers, package markings, SDS and ERG Guide 137. Establish incident command, isolate the area, stay upwind, prevent incompatible contact, control runoff and choose entry or fire-control actions based on monitoring, SDS and local SOP.

Firefighter training notes: Training for UN 1810 should emphasize violent water reaction, hydrogen halide/phosphoric acid fuming, dry-agent selection, downwind vapor control and decontamination. Use ERG 137, SDS and hazmat SOP.

Regulatory context: Phosphorus oxychloride is regulated as a hazardous material for transportation and emergency response purposes. Transportation, workplace exposure, spill reporting, waste handling, storage and environmental requirements may vary by concentration, formulation, quantity and jurisdiction. Verify current requirements through shipping papers, SDS, facility documents and applicable DOT, OSHA, EPA, NFPA, state or local authority guidance.

Storage & handling: Phosphorus oxychloride should be stored in tightly closed compatible containers in a cool, dry, well-ventilated area away from water, moisture, bases, oxidizers/reducing agents where incompatible, heat and unauthorized access. Protect containers from corrosion, leakage and contamination.

Advertisement

UN 1810 Quick Details

UN 1810
Product name: Phosphorus oxychloride
DOT Class: 6
Placard type: Toxic
ERG Guide: 137 (check current ERG)
Initial isolation: ERG 137: isolate spill area immediate 50m in all directions; evacuate downwind 300m initial, 800m if large spill; 1600m evacuation if tank/rail car involved in fire

Common Hazards of UN 1810

  • TOXIC and CORROSIVE phosphorus halide; inhalation, ingestion or skin/eye contact may cause severe injury.
  • Reacts violently with water or moist air, releasing heat, hydrogen chloride and phosphoric acid fumes.
  • Vapors or fumes are heavier than air and may collect in low or confined areas.
  • Liquid, dust, vapor or fumes can burn eyes, skin and respiratory tissue.
  • Fire may produce irritating, corrosive and/or toxic gases.
  • Runoff may spread acidic phosphorus/halide contamination.
  • Containers may rupture or fail when heated or contaminated with water.

Chemical Identity & Physical Properties

Colorless to slightly yellow fuming liquid with a pungent, acrid odor. Fumes heavily in moist air.

Also known asPhosphoryl chloridePhosphoric trichloridePOCl3Phosphorus(V) oxychloridePhosphoryl trichloride
CAS Number10025-87-3
AppearanceColorless to slightly yellow fuming liquid with a pungent, acrid odor. Fumes heavily in moist air.
Flash PointNot applicable (non-flammable liquid)
Boiling Point105.5°C (222°F)
Vapor Density5.3 (much heavier than air)
Water ReactivityReacts violently with water, producing heat and toxic/corrosive fumes (hydrogen chloride and phosphoric acid). Do not apply water directly.
Chemical details are general reference only. Always verify with current SDS, ERG, and SOP/SOG.

Fireground Response Guidance — UN 1810

Extinguishing Media

Use dry chemical, CO2, dry sand, soda ash, lime or other compatible dry media when directed by incident command. Avoid water or foam directly on product unless SDS and incident command confirm a safe use; cool nearby containers from a protected distance.

PPE Requirements

⚠️ Level A or B required; full chemical-resistant suit, SCBA mandatory; prevent any skin or eye contact with liquid or vapors

Use positive-pressure SCBA for vapor, fume, dust, fire or confined-space exposure. Chemical-resistant gloves, boots, eye/face protection and protective clothing should be selected from SDS; Level A may be needed for close entry or unknown concentrations.

Isolation & Evacuation

ERG 137: isolate spill area immediate 50m in all directions; evacuate downwind 300m initial, 800m if large spill; 1600m evacuation if tank/rail car involved in fire
Always confirm protective actions with the current edition of the Emergency Response Guidebook (ERG Guide 137).

First Actions for a UN 1810 Incident

  • CALL 911. Then call the emergency response telephone number on the shipping paper, if available.
  • Keep unauthorized personnel away.
  • Stay upwind, uphill and/or upstream.
  • Avoid breathing vapors, fumes, dust, mist or spray and avoid skin or eye contact.
  • Keep water and moisture away from released product unless incident command confirms a compatible cooling or control use.
  • Do not touch or walk through spilled material unless properly trained and wearing appropriate protective equipment.
  • Ventilate closed spaces before entering, but only if properly trained, equipped, monitored and authorized by incident command.
  • Isolate the spill or leak area and expand the perimeter if vapor, dust, fire involvement, water reaction or unknown concentration is present.
  • Use ERG Guide 137, shipping papers, SDS, air monitoring and incident command for protective actions.
Advertisement

📋 Copy & Share Field Card

UN 1810 — Phosphorus oxychloride
HAZMAT RADIO NOTE — UN 1810 Product: Phosphorus oxychloride Class 6 / Toxic / ERG 137 PPE: Level A or B required; full chemical-resistant suit, SCBA mandatory; prevent any skin or eye contact with liquid or vapors ISOLATION: ERG 137: isolate spill area immediate 50m in all directions; evacuate downwind 300m initial, 800m if large spill; 1600m evacuation if tank/rail car involved in fire ACTION: Stage upwind · Isolate · Deny entry · Request HazmatRADIO

Use for: Quick radio or face-to-face size-up. Short, structured, field-ready.

SMS WhatsApp
=== IC HAZMAT BRIEFING === UN 1810 — Phosphorus oxychloride Class: 6 | Placard: Toxic | ERG Guide: 137 Appearance: Colorless to slightly yellow fuming liquid with a pungent, acrid odor. Fumes heavily in moist air. Water Reactivity: Reacts violently with water, producing heat and toxic/corrosive fumes (hydrogen chloride and phosphoric acid). Do not apply water directly. Extinguishing: Use dry chemical, CO2, dry sand, soda ash, lime or other compatible dry media when directed by incident command. Avoid water or foam directly on product unless SDS and incident command confirm a safe use; cool nearby containers from a protected distance. PPE: Level A or B required; full chemical-resistant suit, SCBA mandatory; prevent any skin or eye contact with liquid or vapors Isolation: ERG 137: isolate spill area immediate 50m in all directions; evacuate downwind 300m initial, 800m if large spill; 1600m evacuation if tank/rail car involved in fire — Key Hazards — • TOXIC and CORROSIVE phosphorus halide; inhalation, ingestion or skin/eye contact may cause severe injury. • Reacts violently with water or moist air, releasing heat, hydrogen chloride and phosphoric acid fumes. • Vapors or fumes are heavier than air and may collect in low or confined areas. — First Actions — • CALL 911. Then call the emergency response telephone number on the shipping paper, if available. • Keep unauthorized personnel away. • Stay upwind, uphill and/or upstream. • Avoid breathing vapors, fumes, dust, mist or spray and avoid skin or eye contact. SOURCE: allfirefighter.com/hazmat/un/phosphorus-oxychloride-un-1810 | Always use current ERG + SOP/SOGIC BRIEFING

Use for: Incident command briefing, staging area whiteboard, or pre-entry team brief.

SMS (short)
UN1810 Phosphorus oxychloride Cls6 ERG137 | allfirefighter.com/hazmat/un/phosphorus-oxychloride-un-1810SMS / 160 CHAR

Use for: Quick text to command or incoming units. Fits in a single SMS.

⚠️ Quick-reference only. Always use current ERG + SOP/SOG for incident-specific actions. Page: https://allfirefighter.com/hazmat/un/phosphorus-oxychloride-un-1810

Related UN Numbers in Class 6

Discovery block for training / quick reference. Always consult the current ERG + your SOP/SOG for operations.
Advertisement

Frequently Asked Questions about UN 1810

UN 1810 is Phosphorus oxychloride, a hazardous material assigned to ERG Guide 137.

No. It is not normally flammable, but water reaction and toxic/corrosive fumes are major hazards.

ERG Guide 137 applies to UN 1810 for initial isolation, protective actions and first response guidance.

UN 1810 presents violent water reaction, toxic/corrosive fume, heavy vapor and acidic-runoff hazards. Avoid water and foam on the product unless specialist guidance confirms a safe use.

Use positive-pressure SCBA for vapor, fume, dust, fire or confined-space exposure. Chemical-resistant gloves, boots, eye/face protection and protective clothing should be selected from SDS; Level A may be needed for close entry or unknown concentrations.

Water or moist air can generate heat and toxic/corrosive fumes. Direct water application should follow ERG, SDS and incident command because reaction or runoff can worsen exposure.
Sources (high level): DOT/PHMSA marking & class concepts + ERG usage principles. This page does not reproduce ERG guide text—always consult the current ERG for incident-specific protective actions.