☣️ UN 2747 • CLASS 6

UN 2747 — tert-Butylcyclohexyl chloroformate

Placard: Toxic. ERG Guide 156. Training/quick-reference only — use current ERG + SOP/SOG for incident-specific actions.

🚒☣️
⚠️ This page is a quick-reference aid. For real incidents: stage upwind, isolate, deny entry, request Hazmat early, and consult the current ERG + SOP/SOG.

UN 2747 is tert-Butylcyclohexyl chloroformate, a toxic corrosive combustible chloroformate assigned to ERG Guide 156. Water reaction and acidic runoff must be controlled.

Hazard overview: TOXIC and CORROSIVE combustible chloroformate liquid; inhalation or skin contact may cause severe injury. Reacts with water or moist air, releasing hydrogen chloride, carbon dioxide, heat and corrosive runoff. Heated vapors may form ignitable mixtures and collect in low or confined areas.

Response guidance: For UN 2747, isolate the spill, stay upwind and use SCBA with chemical protection. Control moisture contact, use compatible dry agents and contain acidic/toxic runoff under SDS and ERG 156.

Firefighter training notes: Training for UN 2747 should emphasize moisture-reactive corrosive fuming, dry-agent choice, SCBA/Level A decisions, decontamination and acidic runoff control. Use ERG 156, SDS and local SOP.

Regulatory context: tert-Butylcyclohexyl chloroformate is regulated as a hazardous material for transport and emergency response. Storage, exposure, spill reporting, waste and fire-code duties depend on quantity, concentration and jurisdiction; verify shipping papers, SDS and local authority requirements.

Storage & handling: tert-Butylcyclohexyl chloroformate should be stored dry in tightly closed compatible containers away from water, moisture, bases, alcohols, amines, heat and unauthorized access. Provide secondary containment.

Advertisement

UN 2747 Quick Details

UN 2747
Product name: tert-Butylcyclohexyl chloroformate
DOT Class: 6
Placard type: Toxic
ERG Guide: 156 (check current ERG)
Initial isolation: ERG 156: isolate spill 25m in all directions; for large spills consider initial downwind evacuation 100m; if tank/rail car involved in fire, isolate 800m

Common Hazards of UN 2747

  • TOXIC and CORROSIVE combustible chloroformate liquid; inhalation or skin contact may cause severe injury.
  • Reacts with water or moist air, releasing hydrogen chloride, carbon dioxide, heat and corrosive runoff.
  • Heated vapors may form ignitable mixtures and collect in low or confined areas.
  • Vapors may travel to ignition sources and flash back when heated.
  • Fire may produce hydrogen chloride, phosgene-type gases and other toxic/corrosive smoke.
  • Runoff may be acidic, toxic and environmentally harmful.
  • Containers may rupture or fail when heated or contaminated with water.

Chemical Identity & Physical Properties

Clear to pale yellow liquid with a pungent, acrid odor. Combustible liquid at room temperature.

Also known astert-Butylcyclohexyl chloroformateChloroformic acid tert-butylcyclohexyl ester4-tert-Butylcyclohexyl chloroformate
CAS Number60613-16-9
AppearanceClear to pale yellow liquid with a pungent, acrid odor. Combustible liquid at room temperature.
Flash Point93C (200F)
Boiling PointApproximately 200-220C (392-428F) with decomposition
Vapor Density7.2 (heavier than air)
Water ReactivityReacts with water releasing HCl gas (hydrochloric acid) and corrosive products; avoid water contact
Chemical details are general reference only. Always verify with current SDS, ERG, and SOP/SOG.

Fireground Response Guidance — UN 2747

Extinguishing Media

Use dry chemical, CO2, dry sand or alcohol-resistant foam if compatible. Avoid direct water on product; water spray may cool exposed containers from protection.

PPE Requirements

⚠️ Level B minimum with SCBA; full face protection and chemical-resistant suit required due to corrosive vapor hazard

Use positive-pressure SCBA and chemical-resistant protective clothing. Level A may be needed for heavy vapor, fuming, splash risk or unknown concentrations.

Isolation & Evacuation

ERG 156: isolate spill 25m in all directions; for large spills consider initial downwind evacuation 100m; if tank/rail car involved in fire, isolate 800m
Always confirm protective actions with the current edition of the Emergency Response Guidebook (ERG Guide 156).

First Actions for a UN 2747 Incident

  • Call 911 and the emergency response number on the shipping paper, if available.
  • Keep unauthorized personnel away and establish incident command.
  • Stay upwind, uphill and upstream.
  • Avoid breathing vapor, dust, mist, smoke or fumes and avoid skin or eye contact.
  • Keep water or moisture contact controlled because it can release heat and corrosive gases.
  • Do not touch damaged containers or spilled material without proper training and PPE.
  • Prevent contaminated liquid, dust, runoff and decontamination waste from spreading.
  • Ventilate confined spaces only after monitoring and only if properly trained and equipped.
  • Use ERG Guide 156, SDS, shipping papers and monitoring to set isolation, evacuation and entry decisions.
Advertisement

📋 Copy & Share Field Card

UN 2747 — tert-Butylcyclohexyl chloroformate
HAZMAT RADIO NOTE — UN 2747 Product: tert-Butylcyclohexyl chloroformate Class 6 / Toxic / ERG 156 PPE: Level B minimum with SCBA; full face protection and chemical-resistant suit required due to corrosive vapor hazard ISOLATION: ERG 156: isolate spill 25m in all directions; for large spills consider initial downwind evacuation 100m; if tank/rail car involved in fire, isolate 800m ACTION: Stage upwind · Isolate · Deny entry · Request HazmatRADIO

Use for: Quick radio or face-to-face size-up. Short, structured, field-ready.

SMS WhatsApp
=== IC HAZMAT BRIEFING === UN 2747 — tert-Butylcyclohexyl chloroformate Class: 6 | Placard: Toxic | ERG Guide: 156 Appearance: Clear to pale yellow liquid with a pungent, acrid odor. Combustible liquid at room temperature. Water Reactivity: Reacts with water releasing HCl gas (hydrochloric acid) and corrosive products; avoid water contact Extinguishing: Use dry chemical, CO2, dry sand or alcohol-resistant foam if compatible. Avoid direct water on product; water spray may cool exposed containers from protection. PPE: Level B minimum with SCBA; full face protection and chemical-resistant suit required due to corrosive vapor hazard Isolation: ERG 156: isolate spill 25m in all directions; for large spills consider initial downwind evacuation 100m; if tank/rail car involved in fire, isolate 800m — Key Hazards — • TOXIC and CORROSIVE combustible chloroformate liquid; inhalation or skin contact may cause severe injury. • Reacts with water or moist air, releasing hydrogen chloride, carbon dioxide, heat and corrosive runoff. • Heated vapors may form ignitable mixtures and collect in low or confined areas. — First Actions — • Call 911 and the emergency response number on the shipping paper, if available. • Keep unauthorized personnel away and establish incident command. • Stay upwind, uphill and upstream. • Avoid breathing vapor, dust, mist, smoke or fumes and avoid skin or eye contact. SOURCE: allfirefighter.com/hazmat/un/tert-butylcyclohexyl-chloroformate-un-2747 | Always use current ERG + SOP/SOGIC BRIEFING

Use for: Incident command briefing, staging area whiteboard, or pre-entry team brief.

SMS (short)
UN2747 tert-Butylcyclohexyl chloroformate Cls6 ERG156 | allfirefighter.com/hazmat/un/tert-butylcyclohexyl-chloroformate-un-2747SMS / 160 CHAR

Use for: Quick text to command or incoming units. Fits in a single SMS.

⚠️ Quick-reference only. Always use current ERG + SOP/SOG for incident-specific actions. Page: https://allfirefighter.com/hazmat/un/tert-butylcyclohexyl-chloroformate-un-2747

Related UN Numbers in Class 6

Discovery block for training / quick reference. Always consult the current ERG + your SOP/SOG for operations.
Advertisement

Frequently Asked Questions about UN 2747

UN 2747 is tert-Butylcyclohexyl chloroformate, assigned to ERG Guide 156.

It is combustible but does not ignite readily; toxic/corrosive exposure is the main hazard.

TOXIC and CORROSIVE combustible chloroformate liquid; inhalation or skin contact may cause severe injury. Reacts with water or moist air, releasing hydrogen chloride, carbon dioxide, heat and corrosive runoff. Heated vapors may form ignitable mixtures and collect in low or confined areas.

Use positive-pressure SCBA and chemical-resistant protective clothing. Level A may be needed for heavy vapor, fuming, splash risk or unknown concentrations.

Use dry chemical, CO2, dry sand or alcohol-resistant foam if compatible. Avoid direct water on product; water spray may cool exposed containers from protection.

Water or moist air can release heat, hydrogen chloride and toxic/corrosive decomposition products.
Sources (high level): DOT/PHMSA marking & class concepts + ERG usage principles. This page does not reproduce ERG guide text—always consult the current ERG for incident-specific protective actions.