☣️ UN 1932 • CLASS 4

UN 1932 — Zirconium scrap

Placard: Spontaneously Combustible. ERG Guide 135. Training/quick-reference only — use current ERG + SOP/SOG for incident-specific actions.

🚒☣️
⚠️ This page is a quick-reference aid. For real incidents: stage upwind, isolate, deny entry, request Hazmat early, and consult the current ERG + SOP/SOG.

UN 1932 is Zirconium scrap, a spontaneously combustible metal scrap assigned to ERG Guide 135. Fine turnings or shavings can ignite and water may generate hydrogen gas.

Hazard overview: UN 1932 presents metal fire, moisture reaction, hydrogen generation and re-ignition hazards. Use dry Class D-compatible methods and avoid water or foam unless specialist guidance approves.

Response guidance: For a UN 1932 incident, responders should verify the product with shipping papers, package markings, SDS and ERG Guide 135. Establish incident command, isolate the area, stay upwind, control ignition or incompatibility hazards, prevent runoff or vapor spread and choose entry/fire-control actions based on monitoring, SDS and local SOP.

Firefighter training notes: Training for UN 1932 should emphasize dangerous-when-wet behavior, flammable gas generation, dry-agent/Class D selection, re-ignition and ignition control. Use ERG 135, SDS and local SOP.

Regulatory context: Zirconium scrap is regulated as a hazardous material for transportation and emergency response purposes. Transportation, workplace exposure, spill reporting, waste handling, storage and environmental requirements may vary by formulation, concentration, quantity and jurisdiction. Verify current requirements through shipping papers, SDS, facility documents and applicable DOT, OSHA, EPA, NFPA, state or local authority guidance.

Storage & handling: Zirconium scrap should be stored dry in compatible sealed containers away from water, moisture, oxidizers, acids where incompatible, ignition sources and unauthorized access. Keep compatible dry extinguishing media available.

Advertisement

UN 1932 Quick Details

UN 1932
Product name: Zirconium scrap
DOT Class: 4
Placard type: Spontaneously Combustible
ERG Guide: 135 (check current ERG)
Initial isolation: ERG 135: isolate 25m all directions; for large spill isolate 50m all directions, evacuate 800m downwind if fire

Common Hazards of UN 1932

  • SPONTANEOUSLY COMBUSTIBLE metal scrap; fine turnings, shavings or dust may ignite in air or moisture.
  • May react with water or moisture to generate heat and flammable hydrogen gas.
  • Metal fires may burn intensely and re-ignite after apparent extinguishment.
  • Water, foam, CO2 or halogenated agents may worsen the fire depending on form and contamination.
  • Fire may produce irritating metal oxide smoke.
  • Runoff or water application may create fire, explosion or contamination hazards.
  • Containers may rupture or explode when heated.

Chemical Identity & Physical Properties

Silvery-gray to black metallic solid in the form of scrap pieces, turnings, or shavings. Odorless.

Also known asZirconium metal scrapZirconium turningsZirconium shavingsZirconium waste
CAS Number7440-67-7
AppearanceSilvery-gray to black metallic solid in the form of scrap pieces, turnings, or shavings. Odorless.
Flash PointNot applicable (pyrophoric solid)
Boiling Point4377C (7911F)
Vapor DensityNot applicable (solid)
Water ReactivityReacts with moisture producing hydrogen gas; may ignite spontaneously
Chemical details are general reference only. Always verify with current SDS, ERG, and SOP/SOG.

Fireground Response Guidance — UN 1932

Extinguishing Media

Use dry sand, dry chemical, dry powder, Class D agent where appropriate, soda ash or other SDS-approved dry media. Do not apply water or foam directly unless specialist guidance confirms compatibility.

PPE Requirements

⚠️ Level B minimum; SCBA required; fire-resistant protective clothing

Use positive-pressure SCBA for smoke, dust, sulfur dioxide/corrosive vapor or fire exposure. Wear chemical-resistant and fire-appropriate protection selected from SDS; avoid moisture contamination.

Isolation & Evacuation

ERG 135: isolate 25m all directions; for large spill isolate 50m all directions, evacuate 800m downwind if fire
Always confirm protective actions with the current edition of the Emergency Response Guidebook (ERG Guide 135).

First Actions for a UN 1932 Incident

  • CALL 911. Then call the emergency response telephone number on the shipping paper, if available.
  • Keep unauthorized personnel away.
  • Stay upwind, uphill and/or upstream.
  • Avoid breathing vapors, fumes, dust, mist, smoke or gas and avoid skin or eye contact.
  • Keep water, foam and moisture away from released product unless incident command confirms a compatible control use.
  • Do not touch or walk through spilled material unless properly trained and wearing appropriate protective equipment.
  • Ventilate closed spaces before entering, but only if properly trained, equipped, monitored and authorized by incident command.
  • Isolate the spill or leak area and expand the perimeter if vapor, dust, fire involvement, gas accumulation or unknown concentration is present.
  • Use ERG Guide 135, shipping papers, SDS, air monitoring and incident command for protective actions.
Advertisement

📋 Copy & Share Field Card

UN 1932 — Zirconium scrap
HAZMAT RADIO NOTE — UN 1932 Product: Zirconium scrap Class 4 / Spontaneously Combustible / ERG 135 PPE: Level B minimum; SCBA required; fire-resistant protective clothing ISOLATION: ERG 135: isolate 25m all directions; for large spill isolate 50m all directions, evacuate 800m downwind if fire ACTION: Stage upwind · Isolate · Deny entry · Request HazmatRADIO

Use for: Quick radio or face-to-face size-up. Short, structured, field-ready.

SMS WhatsApp
=== IC HAZMAT BRIEFING === UN 1932 — Zirconium scrap Class: 4 | Placard: Spontaneously Combustible | ERG Guide: 135 Appearance: Silvery-gray to black metallic solid in the form of scrap pieces, turnings, or shavings. Odorless. Water Reactivity: Reacts with moisture producing hydrogen gas; may ignite spontaneously Extinguishing: Use dry sand, dry chemical, dry powder, Class D agent where appropriate, soda ash or other SDS-approved dry media. Do not apply water or foam directly unless specialist guidance confirms compatibility. PPE: Level B minimum; SCBA required; fire-resistant protective clothing Isolation: ERG 135: isolate 25m all directions; for large spill isolate 50m all directions, evacuate 800m downwind if fire — Key Hazards — • SPONTANEOUSLY COMBUSTIBLE metal scrap; fine turnings, shavings or dust may ignite in air or moisture. • May react with water or moisture to generate heat and flammable hydrogen gas. • Metal fires may burn intensely and re-ignite after apparent extinguishment. — First Actions — • CALL 911. Then call the emergency response telephone number on the shipping paper, if available. • Keep unauthorized personnel away. • Stay upwind, uphill and/or upstream. • Avoid breathing vapors, fumes, dust, mist, smoke or gas and avoid skin or eye contact. SOURCE: allfirefighter.com/hazmat/un/zirconium-scrap-un-1932 | Always use current ERG + SOP/SOGIC BRIEFING

Use for: Incident command briefing, staging area whiteboard, or pre-entry team brief.

SMS (short)
UN1932 Zirconium scrap Cls4 ERG135 | allfirefighter.com/hazmat/un/zirconium-scrap-un-1932SMS / 160 CHAR

Use for: Quick text to command or incoming units. Fits in a single SMS.

⚠️ Quick-reference only. Always use current ERG + SOP/SOG for incident-specific actions. Page: https://allfirefighter.com/hazmat/un/zirconium-scrap-un-1932

Related UN Numbers in Class 4

Discovery block for training / quick reference. Always consult the current ERG + your SOP/SOG for operations.
Advertisement

Frequently Asked Questions about UN 1932

UN 1932 is Zirconium scrap, a hazardous material assigned to ERG Guide 135.

Yes. Fine zirconium scrap can ignite or burn intensely, especially when contaminated or exposed to moisture.

ERG Guide 135 applies to UN 1932 for initial isolation, protective actions and first response guidance.

UN 1932 presents metal fire, moisture reaction, hydrogen generation and re-ignition hazards. Use dry Class D-compatible methods and avoid water or foam unless specialist guidance approves.

Use positive-pressure SCBA for smoke, dust, sulfur dioxide/corrosive vapor or fire exposure. Wear chemical-resistant and fire-appropriate protection selected from SDS; avoid moisture contamination.

Do not apply water directly unless a hazmat specialist confirms compatibility. Water or moisture can increase heat, gas release, ignition or corrosive fuming.
Sources (high level): DOT/PHMSA marking & class concepts + ERG usage principles. This page does not reproduce ERG guide text—always consult the current ERG for incident-specific protective actions.